Under Floor Extract Systems
For airless paint application to structural steelwork
Used technology/requirements
Open shop painting facility to remove overspray from paint application area, volume flow rates 160,000m3/hr (per working cell)
Removal of contaminants from exhaust air to atmosphere in Compliance with the current Environmental protection acts with regard to VOC and particulate emission levels.
Exhaust stack efflux heights and velocities calculated to meet chimney emission regulations.
Heavy duty airless spray application equipment suitable for the application of a range of high build and Zinc rich primers to meet specified film build and protection from corrosion specified by Architects.
Disposable filter technology using multi layer paper filter system for high efficiency and for affordable running costs.
Energy saving control for no paint operation.